<LOGO>
FM Transmitter Measurement Report
Created: 2024-09-28 15-57-45
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
105.70 MHz 3/5, 28 dBuV INFO
Pilot RDS Phase Difference
0.0 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
14 kHz 17 kHz 4455 0,0673
Modulation Power
Limit Measuring Tolerance
11,0 dBr 0,2 dBr
MIN AVE MAX % above 11,2 dBr
3,1 dBr 4,06 dBr 5,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" INFO " F206 0 (No PTY) 0 0 0 0 15:57, 28.09.2024
RT
"14 / 17 - MARC PODEVIN - FRANCEINFO CONSO - FRANCEINFO "
AF EON
103.1, 105.5, 105.7 MHz F201, F207, F202
FM Scope Station: 105.70 MHz, signal: 4/5 (28 dBuV) Max at: 17 kHz MIN: 14 kHz % above 75 kHz: 0,0673 Acquired: 2024/09/28 15:56:42 Total samples: 4455 Equivalent time: 0:03:42 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200
FM Scope MAX: 5,2 dBr MIN: 3,1 dBr AVE: 4,06 dBr % above 11,2 dBr: 0,0 Last value: 3,4 dBr (2024/09/28 15:56:41) Station: 105.70 MHz, signal: 3/5 (28 dBuV) 15:44 15:46 15:48 15:50 15:52 15:54 15:56 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality